Perimeter protection
SensLine
SensLine System of Perimeter Sensors – new technology for protecting facilities
How it works
A sensor every 5 metres. Each one thinks for itself.
We mount a cable with 2 × 4 cm modules every 5 m on the fence. Each module registers movement in three planes and the central unit analyses it separately – so one cable handles different fence types.
- Construction sites
- Industrial sites
- Military units
- Solar farms
- Strategic facilities
* own tests carried out as part of R&D
Comparison
Classic sensor cable vs SensLine
Someone cut the fence
Service gets the exact fault location and the system can test modules every 60 s (Grade 4).
Algorithms
Wind is not an intruder
At wind speeds above 40 km/h a classic cable floods security with false alarms. SensLine AI analyses each sensor's signal and passes on only a real intrusion.
> 40 km/h
Video
SensLine video presentation
Expansion
Connect what you want, where you want
Anywhere on the cable you can add motion detectors, opening sensors, LED lighting of the intrusion point or lock control – and connect it all to another manufacturer's alarm panel. Cost at the level of a classic sensor cable.
- Custom configurationnumber, size and sensitivity of zones per site
- Flexible installationcentral unit up to hundreds of metres away
- On-fence and in-groundUV resistant, anti-tamper
- Fast servicededicated repair kits
Architecture
System components
Range
How much cable one Bridge handles
The maximum cable length depends on the Bridge version, the supply voltage and whether the cable runs in two lines or in a loop.
- Bridge Standard
- Bridge Premium
For the SensLine Standard cable. Above 50 °C reduce lengths by 10%.
Two separate lines (total)
Loop
Example
Sample plan of a secured facility
Use the Adapter to exclude the entrance gate as an unprotected zone, or run the cable over the gate in a loop or bury it under the driveway. Configure remotely via GSM or from a PC over USB.
| Type | Device | Zone 1 | Zone 2 | Zone 3 | Zone 4 | Zone 5 | Zone 6 | Zone 7 | Zone 8 | Zone 9 | Zone 10 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | Reed switch 1 | ✓ | – | – | – | – | ✓ | – | – | – | – |
| 1 | Sensor 1 | ✓ | – | – | – | – | ✓ | – | – | – | – |
| 1 | Sensor 2 | ✓ | – | – | – | – | – | – | – | – | – |
| 1 | Sensor 3 | ✓ | – | – | – | – | – | – | – | – | – |
| 1 | Sensor 4 | ✓ | – | ✓! | – | – | – | – | – | – | – |
| 1 | Sensor 5 | ✓ | – | – | – | – | – | – | – | – | – |
| 1 | Sensor 6 | ✓ | – | – | – | – | – | – | – | – | – |
Full technical specification
| Sensor spacing on the cable | 5 m |
|---|---|
| Intruder location precision | matches sensor spacing |
| Alarm zones | independent |
| Alarm criteria | amplitude and duration |
| Several intruders at once | yes |
| Zone damage detection | yes |
| Connection continuity test | yes |
| Anti-tamper protection | yes |
| Number of zones | up to 208 (16 + 4 × 48) |
| Power consumption | 6–10 W |
|---|---|
| Operating temperature | −40 … +70 °C |
| Relative humidity | 5–95% |
| Power supply | DC 12 V or 12–36 V |
| Interfaces | RS-485, IO, NC, NO |
| Bridge – logic part | 8–13 V · 51 / 100 mA |
| Bridge – sensor part | 12–38 V · max 3 A |
| Cable – current draw | 0.105 A/km |
| Configuration | local or remote (GSM / Gateway) |
Let's design protection for your site
Send us your fence plan – we will count the zones and cable length and pick the right Bridge.